C9020 562 Pdf Demo}
- Click Here To Know More About:
- Film Editing Courses Sydney
Submitted by: Richard Mills
Question: 1
A customer is planning to implement a new IBM Storwize V5030 solution and is evaluating the requirements for implementing disaster recovery with HyperSwap.
Which HyperSwap configuration requirement needs to be part of installation?
A. Both I/O groups and managed disks are at the same site.
B. Configuration with standard topology with all controlenclosures are at the same site.
C. Configure volume mirror relationship with a controller from each I/O group at different sites.
D. Each I/O group and its managed disks are at different sites.
Answer: D
Explanation:
HyperSwap volumes, where copies of a single volume are in different storage pools that are on different sites. The volume is cached in two I/O groups that are on different sites. These volumes can only be created on Storwize V5030 systems when the system topology is HyperSwap.
References:http://www.ibm.com/support/knowledgecenter/STHGUJ_7.7.0/com.ibm.storwize.tb5.770.doc/tbrd4_tbrd4ovr.html
Question: 2
A cloud solution is being planned using the IBM Storwize family to provide storage for multiple clients on IBM Power and Intel hosts.
Which solution provides the necessary storage for the primary site and a disaster recovery location at a data center 1500 kilometers away?
A. Create a four node IBM Storwize V7000 cluster with one I/O Group at the primary data center and the other at the disaster recovery location. Use FlashCopy to copy the volumes from the primary I/O Group to the disaster recovery I/O Group.
B. Create volumeson IBM Storwize V7000 storage at the primary data center and use Global Mirror to create copies on an IBM Storwize V7000 at the disaster recovery location.
C. Create volume mirrors on IBM Storwize V7000 storage at the primary data center with virtualizedexternal IBM Storwize V3700 storage at the disaster recovery location.
D. Create volumes on IBM Storwize V7000 Storage at the primary data center and use Metro to create asynchronous copies on an IBM Storwize V5030 at the disaster recovery location.
Answer: B
Explanation:
Metro Mirror and Global Mirror are technologies that enable you to keep a real-time copy of a disk at a remote site that contains another SVC Cluster or Storwize V7000 system.
Incorrect Answers
A: FlashCopy is a function that allows you to create a point-in-time copy of one of your SVC disks. This might be helpful when performing backups or application testing. These copies may be cascaded upon one another, read from, written to, and even reversed.
These copies are able to conserve storage, if needed, by being space-efficient copies that only record items that have changed from the originals instead of full copies.
C: Volume Mirroring is a function designed to increase high availability of the storage infrastructure. It provides the ability to createup to two local copies of a volume.
References: IBM System Storage SAN Volume Controller and Storwize V7000 Replication Family Services, page 22
http://www.redbooks.ibm.com/redbooks/pdfs/sg247574.pdf
Question: 3
A customer has several large disk systems serving up block data over Fibre Channel that are of varying degree of utilization and needs to constrain growth and manage performance. The disk systems are made by EMC, Huawei, Bull, and IBM.
Which IBM software solution should be discussed?
A. IBM Spectrum Control Base Edition
B. IBM Virtual Storage Center for Storwize
C. IBM Cloud Object Storage
D. IBM Spectrum Scale
Answer: B
Explanation:
IBM VirtualStorage Center for Storwize provides a lower-cost alternative to Fibre Channel-based replication that is easily configurable in existing IP infrastructures, eliminating the need for FCIP routers and dark fibre.
SAN Volume Controller can virtualize IBM andnon-IBM storage (over 170 systems from IBM, EMC, HP, HDS, Sun, Dell, NetApp, Fujitsu, NEC, Bull)
References: IBM Storwize Family Software, (SVC & Storwize), Product Roadmap, page 4
https://www.ibm.com/developerworks/community/files/form/anonymous/api/library/c18c45e6-e212-4b38-a28e-6c74534ba5e2/document/4555d51c-465b-4093-bb06-ca70861e2e3e/media
Question: 4
Which authentication protocol for remote authentication of users is supported by the IBM Storwize V7000 model 524?
A. Lightweight Extensible Authentication Protocol (LEAP)
B. Secure Socket Layer (SSL)
C. Lightweight Directory Access Protocol (LDAP)
D. Challenge Handshake Authentication Protocol (CHAP)
Answer: C
Explanation:
You can use the command-line interface (CLI) to configure the Storwize V7000 to authenticate users against servers implementing the Lightweight Directory Access Protocol (LDAP), including IBM Tivoli Directory Server (ITDS) and Active Directory (AD).
References:http://www.ibm.com/support/knowledgecenter/ST3FR7_6.4.1/com.ibm.storwize.v7000.641.doc/svc_remoteauthentcliLDAP_08070948.html
Question: 5
Which IBM Storwize product allows for scalability up to a maximum of 20 expansion enclosures with a single control enclosure?
A. IBM Storwize V5030
B. IBM Storwize V3700
C. IBM Storwize V5020
D. IBM Storwize V5010
Answer: A
Explanation:
V5030: Standard expansion enclosures: up to 20 standard expansion enclosures per controller.
High-density expansion enclosures: up to 8 high-density expansion enclosures per controller.
Question: 6
An IBM i customer decided to take advantage of the performance of flash-based storage and is implementing an IBM FlashSystem V9000. The customer plans to move all data to the V9000 with native IBM i attachment.
Which connection protocol is required for this environment?
A. FC
B. FTP
C. 10 Gb FCoE
D. InfiniBand
Answer: A
Explanation:
IBM FlashSystem V9000 can be attached to IBM i in the following ways:
* Native connection without using Virtual I/O Server (VIOS)
Native connection with SAN switches can be done with these adapters:
4 Gb Fibre Channel (FC) adapters, feature number 5774 or 5276
8 Gb FC adapters, feature number 5735 or 5273
16 Gb FC adapters, feature number EN0A or EN0B
Direct native connection without SAN switches can be done with these adapters:
4 Gb FC adapters in IBM i connectedto 8 Gb adapters in IBM FlashSystem V9000
16 Gb adapters in IBM i connected to 16 Gb adapters in IBM FlashSystem V9000
* Connection with VIOS in N_Port ID Virtualization (NPIV) mode
There are rules for mapping server virtual FC adapters to the ports in VIOS when implementing IBM i in VIOS NPIV connection.
* Connection with VIOS in virtual SCSI (VSCSI) mode
References:Introducing and Implementing IBM FlashSystem V9000, page 272
http://www.redbooks.ibm.com/redpieces/pdfs/sg248273.pdf
Question: 7
What is the minimum of connections that an IBM Storwize node canister should have to a host according to best practices?
A. 4
B. 1
C. 2
D. 6
Answer: C
Explanation:
The system contains a Storwize V7000 storage system. Each Storwize V7000 single processing unit is a node canister, which is also called a node. The two nodes within their canisters make an I/O group that is attached to the SAN fabric.
Each Storwize V7000 control enclosure requires two Ethernet cables to connect it to an Ethernet switch or hub. One cable connects to port 1 of the left node canister, and the other cable connects to port 1 of the right node canister. A 10/100/1000 Mb Ethernet connection is required for each cable. Both Internet Protocol Version 4 (IPv4) and Internet ProtocolVersion 6 (IPv6) are supported.
Note: For increased redundancy, an optional second Ethernet connection is supported for each Storwize V7000 node canister.
References:http://www.ibm.com/support/knowledgecenter/ST3FR7_7.7.0/com.ibm.storwize.v7000.770.doc/svc_portsandconnect_gen2.html
About the Author: Test Information:Total Questions 60Test Number: C9020-562Vendor Name: IBMCert Name: IBM CERTIFIED SPECIALISTTest Name: IBM Storwize Family Technical Solutions V4Official Site:
examcertify.co.uk
For More Details:
examcertify.co.uk/C9020-562.html
Get20% Immediate Discount on Full Training MaterialDiscount Coupon Code: 79741B6012
Source:
isnare.com
Permanent Link:
isnare.com/?aid=1962334&ca=Computers+and+Technology}